Transformers of 6, 10 kV SZTT TOL-10, TOL-10-I, TOL-10-M, etc.

Measuring current transformers are designed for installation in complete switchgears and serve to transmit a signal of measuring information to measuring instruments and (or) protection and control devices, to isolate secondary connection circuits from high voltage in AC electrical installations for a voltage class up to 10 kV of frequency 50 or 60 Hz.
Transformers for differential protection are supplied by special order. Transformers are manufactured in the climatic version "T" and "UHL" of the placement category 2.1 according to GOST 15150 and are intended for use in enclosed spaces.
Transformers for differential protection are supplied by special order. It is possible to manufacture transformers with different transformation coefficients of the secondary windings. Transformers are equipped with protective transparent covers for separate sealing of secondary terminals (sealing sample).
The TOLK-6 and TOLK-6-I reference measuring current transformers are designed for installation in high-voltage complete mine switchgear (CRU) in networks with a voltage of up to 6 kV of coal and shale mines dangerous for gas and dust. TOLK-6-1 transformers are also used in complete switchgear. Transformers have a climatic version "O", placement category 5.1 according to GOST 15150, TOLK-6-1 transformers can be manufactured in a climatic version "U", placement category 2.
Main Features:- Voltage class: 6 kV;
- Rated primary current: 10-600 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 1.
Reference measuring current transformers TOL-10 are available with one secondary winding for measurement and one secondary winding for protection. Transformers with a rated current of 1000 and 1500 A can be produced with two secondary windings for protection.
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 10-2000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 1; 5P; 10P;
- number of secondary windings: 2 or 3.
Reference measuring current transformers TOL-10-M are manufactured for nominal primary currents of 2500, 3000, 4000 A, with two, three and four secondary windings.
Main Features:- Voltage class: 10 kV;
- Rated primary current: 5-4000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 5P; 10P;
- number of secondary windings: 2, 3 or 4.
Reference measuring current transformers TOL-10-I can be manufactured with a variable transformation coefficient on the "high" and "low" sides, switching the primary or secondary winding, respectively. Transformers for differential protection are supplied by special order. Transformers with the letter "B" in the designation are supplied with flexible secondary terminals with a length of at least 100 mm.
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 5-2000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2, 3 or 4.
The current measuring transformer TOL-10 III UHL1 of the outdoor installation is based on the existing design of the well-proven transformer TOL-10-I and is an addition to the voltage transformer of the outdoor installation ZNOL-10 III UHL1. Included in the package, these transformers can be used on open 10 kV switchgears for electricity metering and line protection, as well as for installation in reclosers.
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 5-2000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2 or 3.
The reference measuring current transformer TOL-10-8 (replaces the transformer TLM-10) for differential protection are supplied by special order. Transformers of versions 8.5 and 8.6 are supplied with flexible terminals with a length of at least 100 mm.
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 10-2000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2 or 3.
Reference measuring current transformers TOL-10-9
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 5-2000 A
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2, 3 or 4.
The reference measuring current transformers TOL-10-11 have reduced overall dimensions – only 210 mm in length!
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 10-3000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2.
Current measuring transformers TOL-10-IM-2 (-3;-4)
Main Features:- Voltage class: 6, 10 kV;
- Rated primary current: 10-2000 A;
- Rated secondary current: 1-5 A;
- Accuracy class: 0.5; 0.5S; 0.2; 0.2S; 10P;
- number of secondary windings: 2, 3 or 4.
All SZTT products
About SZTT
-
TECHNOLOGY INTENSITY
Constant search and implementation of new design and technological solutions, modern materials, reliable components, advanced world experience. -
ENERGY EFFICIENCY
A significant reduction in no-load losses, a significant increase in the electrodynamic resistance of the windings in case of a short circuit, an improvement in weight and size characteristics, a reduction in installation and operating costs. -
ULTIMATE UTILITARIANISM
It corresponds to the entire range of needs and functions in the field of electricity and power. A wide range of transformers with any combination of accuracy classes and the possibility of application in specific and extreme conditions.
Information Board SZTT
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for SZTT products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89